FiO₂, or Fraction of Inspired Oxygen, refers to the percentage or fraction of oxygen in the air mixture that is inhaled by a patient. Room air naturally contains approximately 21% oxygen (FiO₂ = 0.21). When supplemental oxygen is delivered—commonly through nasal cannulas, masks, or ventilators—FiO₂ increases proportionally. The FiO₂ calculator estimates this new oxygen fraction based on the flow rate of supplemental oxygen, offering a fast, standardized method to gauge respiratory support intensity. This metric is essential for evaluating a patient’s oxygenation status and guiding adjustments to oxygen therapy in real-time.
Detailed Explanation of the Calculator’s Working
The FiO₂ calculator operates on a linear estimation model that assumes an average increase of 4% in FiO₂ per liter of oxygen flow. Starting from ambient air at 21% oxygen, the tool adds 4% for every additional liter per minute (L/min) of oxygen delivered. For example, a flow of 2 L/min would result in an FiO₂ of approximately 29%. While this estimation works well for low to moderate flows via nasal cannula, it becomes less accurate at high flow rates or when using advanced delivery systems like non-rebreathers or ventilators. The calculator helps clinicians make quick, informed decisions.
Formula with Variables Description

Where:
FiO2
is the estimated fraction of inspired oxygen0.21
represents 21% oxygen in room air0.04
is the estimated increase per liter of oxygenOxygen Flow Rate
is the supplemental oxygen in L/min
This formula assumes use of a standard nasal cannula in adult patients.
Reference Table: FiO₂ Estimations by Flow Rate
Oxygen Flow Rate (L/min) | Estimated FiO₂ (%) |
---|---|
1 | 25 |
2 | 29 |
3 | 33 |
4 | 37 |
5 | 41 |
6 | 45 |
Note: These are general estimates for nasal cannula usage in adults. Actual FiO₂ may vary based on patient condition, tidal volume, and delivery device.
Example
Suppose a patient is receiving supplemental oxygen at a rate of 4 L/min via nasal cannula. To estimate the FiO₂:
FiO2 = 0.21 + (0.04 * 4)
FiO2 = 0.21 + 0.16
FiO2 = 0.37 or 37%
This result means the patient is breathing air with approximately 37% oxygen content, significantly higher than room air. This helps clinicians evaluate whether the current support is sufficient or needs adjustment.
Applications
Clinical Respiratory Care
The FiO₂ calculator is indispensable in managing patients with respiratory distress, chronic obstructive pulmonary disease (COPD), or post-surgical needs. It ensures appropriate oxygenation levels are maintained without causing oxygen toxicity.
Emergency Medical Response
In ambulance or field settings, responders often lack advanced monitoring tools. The FiO₂ calculator offers a rapid estimation method to ensure effective oxygen delivery under pressure.
Anesthesia and Postoperative Monitoring
Anesthesiologists and surgical teams use FiO₂ to maintain proper oxygenation during and after procedures. Calculating FiO₂ helps tailor oxygen flow to avoid hypoxemia and monitor gas exchange.
Most Common FAQs
FiO₂ stands for the fraction of inspired oxygen and measures the concentration of oxygen a patient inhales. It is critical in assessing oxygenation status, especially in respiratory-compromised patients. Accurate FiO₂ estimation enables healthcare professionals to titrate oxygen therapy safely and prevent both under- and over-oxygenation, which can have serious clinical consequences.
The calculator provides a close estimate based on standard nasal cannula usage and flow rates up to 6 L/min. While it’s not a replacement for arterial blood gas (ABG) analysis or pulse oximetry, it serves as a fast and practical guide, especially in emergency settings or when high-precision tools are unavailable.
Yes, FiO₂ can vary depending on the patient’s breathing pattern, tidal volume, and the oxygen delivery system used. For instance, a non-rebreather mask or high-flow nasal cannula can deliver higher and more consistent FiO₂ levels than a standard nasal cannula, even at the same flow rate.